Availability: | |
---|---|
Quantity: | |
LGMCD-9000E
OEM
9018193010
Compact and lightweight design
7" color TFT screen, folding 90 degrees
Built-in high dot matrix thermal printer with long life
A standard patient event marker and a clinical event marking button to mark clinical events separately.
Auto fetal movement are available.
Multi-crystals, wide beam forming, high sensitivity ultrasound transducer, low ultrasound power
AC or Li-ion battery
More than 12 hours data storage, which can be recalled and reprinted.
Technical Specifications
Fetal Heart Rate | Multi-crystal,pulsed doppler,high sensitive |
Transducer Strengh | <5mW/cm2 |
Working frequency | 1.0MHz |
Signal processing | special DSP system and mode recognization |
Measurement range | 50~210 bpm |
Alarm Range | High: 160 170 180 190 bpm Low : 90 100 110 120 bpm |
The largest audio output power | 1.5W |
TOCO
Measurement range: 0~100units
Battery working time: 2 hours(no printer working)
Speaker: 1W
Power Supply: AC 220V±20%,50Hz or 8.4V Li-battery
Power consumption: <20W
Working Environment
Temperature: 10~40 ºC, RH: 10~80%
Transducer Acoustic Output
Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2 and the spatial-peak temporal-ave rage intensity does not exceed 100mW/cm2
Dimension: 295W×240D×73H×mm
Net weight: 1.75kg
Standard: FHR, TOCO, FM
Optional: Twins,FAS(Fetal acoustic simulator)
Compact and lightweight design
7" color TFT screen, folding 90 degrees
Built-in high dot matrix thermal printer with long life
A standard patient event marker and a clinical event marking button to mark clinical events separately.
Auto fetal movement are available.
Multi-crystals, wide beam forming, high sensitivity ultrasound transducer, low ultrasound power
AC or Li-ion battery
More than 12 hours data storage, which can be recalled and reprinted.
Technical Specifications
Fetal Heart Rate | Multi-crystal,pulsed doppler,high sensitive |
Transducer Strengh | <5mW/cm2 |
Working frequency | 1.0MHz |
Signal processing | special DSP system and mode recognization |
Measurement range | 50~210 bpm |
Alarm Range | High: 160 170 180 190 bpm Low : 90 100 110 120 bpm |
The largest audio output power | 1.5W |
TOCO
Measurement range: 0~100units
Battery working time: 2 hours(no printer working)
Speaker: 1W
Power Supply: AC 220V±20%,50Hz or 8.4V Li-battery
Power consumption: <20W
Working Environment
Temperature: 10~40 ºC, RH: 10~80%
Transducer Acoustic Output
Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2 and the spatial-peak temporal-ave rage intensity does not exceed 100mW/cm2
Dimension: 295W×240D×73H×mm
Net weight: 1.75kg
Standard: FHR, TOCO, FM
Optional: Twins,FAS(Fetal acoustic simulator)