LG-HD9000C Defibrillator for Medical Use

Physical characteristics:Monophasic
Main unit: Portable
Dimensions:L320xW205xH410
Weight:9.8kg
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button
  • LGHD-9000C

  • OEM

Technical specifications   
DEFIBRILLATOR.
(1)  Defibrillator type   Manual, Synchronized, Asynchronized,                                                                               (2)  Energy accuracy     ∠+1%
(3)  Energy selection    0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of 50)
(4)  Charging time       Maximum 10 seconds to 360 Joules
(5)  Standard Adult/Pediatric Paddles  Reusable external adult paddles (pediatric paddles integrated)            
.Power requirements.
(a) AC Power supply                  100V~240V,50Hz/60 Hz
(b) Vehicle Voltage(Option)          DC 12V
Internal Battery Backup
(1)Battery type          Rechargeable lead-acid battery  (12V 2.0Ah  X2)
(2)Charging time         Time-Minimum of 4 hours for full charging    
(3)Battery charging      During AC Power Supply operation of the device.
(4)Charging /Low Battery Indication      Red LED                
(5)Battery Capacity      100% of the battery will provide 120-min monitoring; and 35 discharges at 360 joules.
Display
-LCD Dimensions        7-inch
-Type                  High resolution true-color graphic
-Resolution            480X234
ECG
ECG lead: 1, 2, 3, AVR, AVL, AVF, V1~V6
S-T segment analysis: -2.0~2.0mv 
Arrhythmia analysis: yes 
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat(5 minutes) 
Method: Automatic oscillation 
Cuff type: standard Adult; optional Pediatric/Neonatal
Temperature
Measurement range 20~45ºC
Resolution 0.1ºC
 
Pulse Oximetry(spO2)
Display :spo2 value, pulse histogram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe :standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
 
Pulse range 
Pulse range: 0-255bpm
Standard parameter & configuration
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
Optional parameter
Recorder, Li-ion battery (11.1V 4Ah  X2)