Availability: | |
---|---|
Quantity: | |
LGSE-3D
OEM
9018110000
· Simultaneously 12 lead signal acquisitions.
· Digital filter to prevent baseline drift and automatic positioning of the baseline provide accurate ECG trace.
· Able to detect and alarm on electrode disconnection.
· LED indicator and LCD display show operation status of the unit.
· Isolated input circuit guarantees safety standard in compliance to Class I type CF.
· AC/Rechargeable battery supports continuous operation when AC power supply is not available. For the battery operation, ECG(SE-3D) is equipped with a battery charger and a system for battery capacity management and protection.
· Compact size.
Specifications
Lead: Standard or Cabrera 12 leads,
Simultaneously 12 leads acquisition
Sampling rate 1000Hz(1ms)
Frequency Response: 0.05 ~ 150Hz
Time Constant: ≥3.2s
CMRR: > 100dB
Input Circuit: < 0.1 mA
Noise Level:
Polarization Voltage:
≤ 8 m Vp∽p
± 500mV
Sensitivity valve: 20 mV
Calibration Voltage: 1mV ± 0%
Filter: AC: 50Hz-20dB(or 60Hz); EMG filter:25-35-45Hz-3dB;
Drift filter: 0.5Hz -3dB
Sensitivity: 1.25, 2.5, 5, 10, 20,40mm/mV± 2%
Paper Speed: 5, 6.25, 10, 12.5, 25, 50mm/s ± 3%
Recording MODE: Thermal array printer
8 dot/mm(Vertical) 40 dot/mm(Horizontal, 25mm/s)
Paper Size: 80mm´15m, thermal roll paper
· Simultaneously 12 lead signal acquisitions.
· Digital filter to prevent baseline drift and automatic positioning of the baseline provide accurate ECG trace.
· Able to detect and alarm on electrode disconnection.
· LED indicator and LCD display show operation status of the unit.
· Isolated input circuit guarantees safety standard in compliance to Class I type CF.
· AC/Rechargeable battery supports continuous operation when AC power supply is not available. For the battery operation, ECG(SE-3D) is equipped with a battery charger and a system for battery capacity management and protection.
· Compact size.
Specifications
Lead: Standard or Cabrera 12 leads,
Simultaneously 12 leads acquisition
Sampling rate 1000Hz(1ms)
Frequency Response: 0.05 ~ 150Hz
Time Constant: ≥3.2s
CMRR: > 100dB
Input Circuit: < 0.1 mA
Noise Level:
Polarization Voltage:
≤ 8 m Vp∽p
± 500mV
Sensitivity valve: 20 mV
Calibration Voltage: 1mV ± 0%
Filter: AC: 50Hz-20dB(or 60Hz); EMG filter:25-35-45Hz-3dB;
Drift filter: 0.5Hz -3dB
Sensitivity: 1.25, 2.5, 5, 10, 20,40mm/mV± 2%
Paper Speed: 5, 6.25, 10, 12.5, 25, 50mm/s ± 3%
Recording MODE: Thermal array printer
8 dot/mm(Vertical) 40 dot/mm(Horizontal, 25mm/s)
Paper Size: 80mm´15m, thermal roll paper