Sample types: serum, plasma, urine, cerebrospinal fluid, etc
Analysis methods: one point endpoint method, two point endpoint method, rate method, fixed time method
Working speed: constant speed 200 test/hour
Single and dual wavelength test
24-hour continuous boot, emergency priority insertion, automatic predilution, automatic retest, serum information, remote diagnosis
Test scope: clinical biochemistry, immunity transmission turbidity, therapeutic drug monitoring, etc
Sample & Reagent System | Sample Positions | 49 sample positions |
Sample Volume | 2~70µl | |
Reagent Volume | 20~350µl | |
Probe | High precision inner and outer wall polishing type | |
Probe Washing | Three-dimensional inner and outer wall cleaning technology, Automatic cleaning | |
Reagent Cooling | 2~12℃, refrigerated continuously for 24 hours | |
Optical System | light source | Imported long life halogen lamp |
Spectroscopic method | Post spectroscopic technique | |
Wavelength | 340—800nm | |
wavelength accuracy | <±1nm | |
Reaction System | Cuvettes | Semi-permanent organic glasses are available |
reaction disc | disc type | |
constant temperature system | 37±0.2℃, Real-time temperature display | |
reaction mixture volume | 120~450µl |
Sample types: serum, plasma, urine, cerebrospinal fluid, etc
Analysis methods: one point endpoint method, two point endpoint method, rate method, fixed time method
Working speed: constant speed 200 test/hour
Single and dual wavelength test
24-hour continuous boot, emergency priority insertion, automatic predilution, automatic retest, serum information, remote diagnosis
Test scope: clinical biochemistry, immunity transmission turbidity, therapeutic drug monitoring, etc
Sample & Reagent System | Sample Positions | 49 sample positions |
Sample Volume | 2~70µl | |
Reagent Volume | 20~350µl | |
Probe | High precision inner and outer wall polishing type | |
Probe Washing | Three-dimensional inner and outer wall cleaning technology, Automatic cleaning | |
Reagent Cooling | 2~12℃, refrigerated continuously for 24 hours | |
Optical System | light source | Imported long life halogen lamp |
Spectroscopic method | Post spectroscopic technique | |
Wavelength | 340—800nm | |
wavelength accuracy | <±1nm | |
Reaction System | Cuvettes | Semi-permanent organic glasses are available |
reaction disc | disc type | |
constant temperature system | 37±0.2℃, Real-time temperature display | |
reaction mixture volume | 120~450µl |